Free shipping for all ordes over $500+

ComAp Inteli AIN8

ComAp Inteli AIN8

$781.00

Datasheet

Product description

Peripheries dedicated to expand number of I/Os of the main ComAp controller

Supports wide range of sensor types and characteristics Connection with the main ComAp controller over CAN bus (up to 200 m length)

Extension modules are compatible with

InteliSysNT BaseBox, InteliSysNTC BaseBox, InteliSys GAS, InteliSysNTC Hybrid, InteliSysNT BaseBox Marine

InteliGenNT, InteliGenNT BaseBox, InteliGenNTC BaseBox Marine

InteliMainsNT, InteliMainsNT BaseBox,

InteliMainsNTC BaseBox

InteliDrive DCU Marine, InteliDrive DCU InteliGen4 200, InteliGen 200, InteliGen 500 G2,

InteliGen 500, InteliGen 1000, InteliLite(3) AMF25,

InteliLite(3) AMF20, InteliLite(3) MRS16, Inteli(3) MRS 11, all controllers from InteliLite 4 family, InteliNeo 6000, InteliNeo 5500, InteliMains 210,

InteliMains 1010.

Key features

Analog input: 8 channels Impulse/RPM input: 1 channel

Order code: I-AIN8

Extension Peripheral Modules

 

 

 

Supported sensors: Pt100, Pt1000 Ni100, Ni1000 (0)4 - 20 mA

± 20 mA

0 - 250 Ω, 0 - 2400 Ω, 0 - 10 kΩ

± 1 V DC, 0 - 10 V DC, 0 - 5 V DC

Lambda probe

Application overview

Peripheral extension module for the controllers CAN bus connectivity

Connects analog sensors (via Analog IN) Connects impulse sensor (via Impulse IN

 

 

Technical data

Power supply

 

Power supply 8 to 36 V DC
 

Power consumption

35 mA a @ 24 V ÷ 100

mA at 8 V

Operating conditions

 

Operating temperature - 30°C to + 70°C
Storage temperature - 40°C to + 80°C
Operation humidityn 95% w/o condensation
 

Vibrations

5-25 Hz, ±1.6 mm, 25-100

Hz, a = 4 g

Shocks a = 200 m/s2
Heat radiation 3 W

Analog inputs (not galvanic separated)

 

 

Voltage

range: 0-10V

accuracy: ± 0,25 % of actual value ± 25 mV

 

Current

range: ± 20mA accuracy: ± 0,25 % of actual value ±

50 μA

 

 

Resistance

range: 0- 10 kΩ accuracy: resistance: ± 0,5 % of actual value + ± 2 Ω_Pt100, Pt1000, Ni100,

Ni1000 ± 2,5°C

Impulse / RPM input

 

 

RPM

level of signal: 2(6) Vpk-pk ÷ 70 Vpk-pk

frequency range 4 Hz ÷ 10 kHz

 

 

Impulse

Measurement of pulses by norm DIN 43864 and norm IEC 62053-31–

equipment class A. for flow meter pulses: VHmax = 30 V, Imax=30 mA,

Tonmin =10 ms,Toffmin = 10 ms, OC

General information

 

Protection IP20
 

 

 

 

Impulse

CAN bus is galvanic separated from the measurement and power supply.

All analog inputs are galvanic separated from power supply and CAN bus. Analog inputs are not

galvanic separated

between channels.

Category
Share This Items :

Description

Datasheet

Product description

Peripheries dedicated to expand number of I/Os of the main ComAp controller

Supports wide range of sensor types and characteristics Connection with the main ComAp controller over CAN bus (up to 200 m length)

Extension modules are compatible with

InteliSysNT BaseBox, InteliSysNTC BaseBox, InteliSys GAS, InteliSysNTC Hybrid, InteliSysNT BaseBox Marine

InteliGenNT, InteliGenNT BaseBox, InteliGenNTC BaseBox Marine

InteliMainsNT, InteliMainsNT BaseBox,

InteliMainsNTC BaseBox

InteliDrive DCU Marine, InteliDrive DCU InteliGen4 200, InteliGen 200, InteliGen 500 G2,

InteliGen 500, InteliGen 1000, InteliLite(3) AMF25,

InteliLite(3) AMF20, InteliLite(3) MRS16, Inteli(3) MRS 11, all controllers from InteliLite 4 family, InteliNeo 6000, InteliNeo 5500, InteliMains 210,

InteliMains 1010.

Key features

Analog input: 8 channels Impulse/RPM input: 1 channel

Order code: I-AIN8

Extension Peripheral Modules

 

 

 

Supported sensors: Pt100, Pt1000 Ni100, Ni1000 (0)4 - 20 mA

± 20 mA

0 - 250 Ω, 0 - 2400 Ω, 0 - 10 kΩ

± 1 V DC, 0 - 10 V DC, 0 - 5 V DC

Lambda probe

Application overview

Peripheral extension module for the controllers CAN bus connectivity

Connects analog sensors (via Analog IN) Connects impulse sensor (via Impulse IN

 

 

Technical data

Power supply

 

Power supply 8 to 36 V DC
 

Power consumption

35 mA a @ 24 V ÷ 100

mA at 8 V

Operating conditions

 

Operating temperature - 30°C to + 70°C
Storage temperature - 40°C to + 80°C
Operation humidityn 95% w/o condensation
 

Vibrations

5-25 Hz, ±1.6 mm, 25-100

Hz, a = 4 g

Shocks a = 200 m/s2
Heat radiation 3 W

Analog inputs (not galvanic separated)

 

 

Voltage

range: 0-10V

accuracy: ± 0,25 % of actual value ± 25 mV

 

Current

range: ± 20mA accuracy: ± 0,25 % of actual value ±

50 μA

 

 

Resistance

range: 0- 10 kΩ accuracy: resistance: ± 0,5 % of actual value + ± 2 Ω_Pt100, Pt1000, Ni100,

Ni1000 ± 2,5°C

Impulse / RPM input

 

 

RPM

level of signal: 2(6) Vpk-pk ÷ 70 Vpk-pk

frequency range 4 Hz ÷ 10 kHz

 

 

Impulse

Measurement of pulses by norm DIN 43864 and norm IEC 62053-31–

equipment class A. for flow meter pulses: VHmax = 30 V, Imax=30 mA,

Tonmin =10 ms,Toffmin = 10 ms, OC

General information

 

Protection IP20
 

 

 

 

Impulse

CAN bus is galvanic separated from the measurement and power supply.

All analog inputs are galvanic separated from power supply and CAN bus. Analog inputs are not

galvanic separated

between channels.

Additional information

Weight 1 kg
Dimensions 25 × 16 × 10 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Far far away, behind the word mountains, far from the countries Vokalia and Consonantia there live the blind texts.